A generally recognized acceptable method of sterilizing the lyophilizer is through the use of moist steam under pressure.
一个可以接受的冻干机灭菌方法是使用湿润的蒸汽在一定的压力下进行灭菌。
Once filled and partially stoppered, vials are transported and loaded into the lyophilizer.
一旦灌装和半加塞,瓶子将被摆放到冻干机。
In order to correct this type of problem, another manufacturer installed a vertical laminar flow hood between the filling line and lyophilizer.
为了解决这类问题,一些生产商在灌装线和冻干机之间安装层流罩。
Thus, the dosage units lie directly on the lyophilizer shelf.
从而药物直接摆放在冻干机的板层上。
The transfer and handling, such as loading of the lyophilizer, should take place under primary barriers, such as the laminar flow hoods under which the vials were filled.
传递和操作(如摆放到冻干机)应处于主要的屏障保护下,例如灌装后的瓶子处于层流罩的保护下。
apparatus, lyophil
低压冻干器
For example, one fabricator installed an oil trap in the line between the vacuum pump and chamber in a lyophilizer with an internal condenser.
例如有的制造商在真空泵和前箱间安装了有内部冷凝器的捕油器。
lyophil apparatus
冻干器
Keywords lyophilizer;alternate vacuum defrosting;vacuum control;aseptic technique;
冻干机;交替真空除霜;真空控制;无菌技术;
Obviously, the lyophilizer chamber is to be sterilized between batches because of the direct means of contamination.
冻干机在不同批之间灭菌是因为污染问题。
After sterilization of the lyophilizer and aseptic loading, the initial step is freezing the solution.
冻干机灭菌和无菌摆放后的第一个步骤是冷冻溶液。
Leakage into a lyophilizer may originate from various sources.
冻干机的泄漏有不同的来源。
The lyophilizer should also have the necessary instrumentation to control and record the key process parameters.
冻干机要有必须的仪器控制和记录关键的过程参数。
In the transport of vials to the lyophilizer, since they are not sealed, there is concern for the potential for contamination.
在传递瓶子到冻干机里,由于瓶子不是密闭的,所以存在潜在的污染可能性。
The typical single door lyophilizer opens in the clean area only, and contamination between loads would be minimal.
在单门的箱体上,门只在洁净区打开,装载过程中的污染最小。
Transporting the partially stoppered containers to the lyophilizer and loading into the chamber under aseptic conditions.
在无菌条件下转移半加塞的容器到冻干机中,放置在前箱中。
The sterilization of the lyophilizer is one of the more frequently encountered problems noted during inspections.
在检查过程中,冻干机的灭菌是被提问到的最多的问题。
Design of large-capacity lyophilizer for medicinal raw material
大型原料药用冻干机设计
For a double door system unloading the lyophilizer in a non-sterile environment, other problems may occur.
对于双门箱体,出料门在非无菌区域。
For most cycles, stoppering occurs within the lyophilizer.Typically, the lyophilizer has some type of rod or rods (ram) which enter the immediate chamber at the time of stoppering.
很多循环中全加塞在冻干机里完成,冻干机里有一些螺杆,在全加塞时使用。
One manufacturer as a means of correction developed a laminar flow cart to transport the vials from the filling line to the lyophilizer.
有的生产商的补救措施是使用层流车,在灌装线和冻干机之间传递瓶子。
Keywords Aidi lyophilizer;preparation procedure;anti-tumor activity;quality control methods;pharmacokinetics;
注射用艾迪(冻干);制剂工艺;抗肿瘤活性;质量控制方法;药物动力学;
After filling, dosage units are transported to the lyophilizer by metal trays.
灌装后药物通过金属托盘传递到冻干机里。
It would seem very difficult for a manufacturer to be able to demonstrate satisfactory validation of sterilization of a lyophilizer by chemical "treatment".
生产商很难证明使用化学处理的方法进行灭菌的验证是令人满意的。
lyophil preservation
真空冷冻干燥保藏
The stopper is placed on top of the vial and is ultimately seated in the lyophilizer.
胶塞加载在瓶子的顶部,最终在冻干机内定位。
It was also observed that some of the partially filled vials were loaded into the lyophilizer.
观察到一些部分灌装的产品被装载到冻干机。
Other manufacturers building new facilities have located the filling line close to the lyophilizer and have provided a primary barrier extending from the filling line to the lyophilizer.
还有的生产商建造新的车间时,将灌装线和冻干机摆放的很近,并且在灌装机和冻干机之间安装主要的屏障。
Usually, the bottom of the trays are removed after the dosage units are loaded into the lyophilizer.
通常当药物摆放到冻干机里后,托盘底部要被抽走。
Effect of Pre-freezing Temperature and Lyophilizer Shelf Temperature on Recovery of Red Blood Cells after Lyophilization
预冻温度和冻干机搁板温度对冷冻干燥红细胞的影响